The total number of temperature measurement modules that can be created on the
device, screen based or geolocated, of any type (spots or boxes).
The total number of spot measurement modules that can be loaded simultaneously on the
screen by the device. A value of 0 shall be used to indicate no support for Spots.
The total number of box measurement modules that can be loaded simultaneously on the
screen by the device. A value of 0 shall be used to indicate no support for Boxes.
Specifies valid ranges for the different radiometry parameters used for temperature calculation.
Describes valid ranges for the different radiometry parameters used for accurate temperature calculation.
Valid range of temperature values, in Kelvin.
Valid range of emissivity values for the objects to measure.
Valid range of distance between camera and object for a valid temperature reading, in meters.
Valid range of relative humidity values, in percentage.
Valid range of temperature values, in Kelvin.
Valid range of atmospheric transmittance values.
Valid range of temperature values, in Kelvin.
Valid range of external optics transmittance.
Screen coordinates, if spot is currently on screen. Assumes normalized screen limits (-1.0, 1.0).
Absolute orientation of the PTZ Vector with the Spot on screen. If no PTZVector is present
the spot shall behave as a screen element, and stay on the same screen coordinates as the PTZ
moves (like a head up display mask). If PTZVector is present the Spot element shall appear on
display only when contained in the Field of View. In this case SpotScreenCoords shall be
reported as relative to PTZVector.
Not present parameter means the Device shall use its value from Global Parameters in Thermal Service.
Unique identifier for this Spot Temperature Measurement Analytics Module.
Indicates if the Temperature Measurement Item is enabled to provide temperature readings.
Screen coordinates, if box is currently on screen. Assumes normalized screen limits (-1.0, 1.0).
Absolute orientation of the PTZ Vector with the Box on screen. If no PTZVector is present
the box shall behave as a screen element, and stay on the same screen coordinates as the PTZ
moves (like a head up display mask). If PTZVector is present the Box element shall appear on
display only when contained in the Field of View. In this case BoxScreenCoords shall be
reported as relative to PTZVector.
Not present parameter means the Device shall use its value from Global Parameters in Thermal Service.
Unique identifier for this Box Temperature Measurement Analytics Module.
Indicates if the Temperature Measurement Item is enabled to provide temperature readings.
Not present means Global Parameters from Thermal Service are being used.
Not present means Global Parameters from Thermal Service are being used.
Specifies valid ranges for thresholds and reference parameters used for triggering radiometric rules.
Specifies valid rule conditions for temperature comparisions in radiometric rules.
Specifies temperature measurement types provided by radiometry analytics modules in the device.
Describes valid ranges for radiometric rule condition thresholds and reference parameters.
Valid range of temperature values, in Kelvin.
Valid range of hysteresis time interval for temperature conditions, in seconds.
Valid range of temperature hysteresis values, in Kelvin.
Indicates which of the temperature values provided by the input Analytics Module
shall be used by the rule. In the case of Analytics Modules providing a single
Temperature Value (e.g. Spot) this parameter is ignored, and is therefore optional.
Indicates the type of temperature condition to check.
Indicates the temperature reference value the rule shall be checked against.
Indicates the time interval during which the rule condition shall be met to trigger an event.
Indicates the width in Kelvin of the temerature hysteresis band to be considered by the rule.
Reference Token to the Temperature Measurement Analytics Module providing the Temperature on which rule is defined.
Indicates if the Temperature Rule is enabled to provide temperature alarm events.